Updated · Maxmoc Motor Works engineering team
1. New set or installed set
Every engine for genset use up to 800 kW made, assembled or imported in India needs CPCB IV+ type approval and conformity-of-production certification from ARAI, ICAT or IIP before it can be sold or used. That is the engine maker’s route, and the aftertreatment is part of the approved package.
A DG set that is already installed is not covered by CPCB IV+ type approval. Where the pollution control board or CAQM requires it, the route is a retrofit emission control device (RECD) with at least 70 % particulate capture.
2. Match the CPCB IV+ power band
The aftertreatment column is Maxmoc engineering guidance, not part of the notification. The right package depends on engine-out emissions and duty cycle.
- Up to 19 kW
- NOx + HC 4.7–7.5 g/kWh, PM 0.30 g/kWh: DOC, optional DPF
- 19 to 56 kW
- NOx + HC 4.7 g/kWh, PM 0.03 g/kWh: DOC + DPF, AUS 32-free SCR
- 56 to 560 kW
- NOx 0.40 g/kWh, PM 0.02 g/kWh: DOC + DPF + SCR + ammonia-slip catalyst
- 560 to 800 kW
- NOx 0.67 g/kWh, PM 0.03 g/kWh: DOC + DPF + SCR + ammonia-slip catalyst
- Full table and sources
- CPCB IV+ emission norms
3. Match the product to the rating
- 15–50 kW
- Compact SCR Module
- 19–75 kW
- Urea-Free SCR System
- 50–150 kW
- DOC + DPF System
- 75–800 kW
- Urea SCR System
- 1,000–10,000 kVA
- Integrated DPF + SCR + ASC Catalyst
- Installed sets up to 800 kW
- Retrofit Emission Control Kit (RECD)
4. Look at how the set runs
Standby sets that run cold or at low load for long periods do not always get hot enough for passive soot burn-off. The Oxidation Booster (15–800 kW) raises the catalyst inlet temperature quickly, and the Active Regeneration Module (up to 1,600 kW) clears the DPF whatever the load.
Every system is sized inside the engine maker’s backpressure limit, so rated output is maintained.
5. Plan for monitoring and service
Online Emission Monitoring gives live status, alerts and regeneration logs for RECD and SCR fleets. Ash cleaning, spares, calibration updates and remote diagnostics through the aftertreatment controller keep the system inside its limits.