Skip to content
GuideSelection guide

Choosing emission control for a DG set

The right system depends on three things: whether the set is new or already installed, its power rating under the CPCB IV+ power bands, and how it actually runs. Here is how to narrow it down.

Updated · Maxmoc Motor Works engineering team

1. New set or installed set

Every engine for genset use up to 800 kW made, assembled or imported in India needs CPCB IV+ type approval and conformity-of-production certification from ARAI, ICAT or IIP before it can be sold or used. That is the engine maker’s route, and the aftertreatment is part of the approved package.

A DG set that is already installed is not covered by CPCB IV+ type approval. Where the pollution control board or CAQM requires it, the route is a retrofit emission control device (RECD) with at least 70 % particulate capture.

2. Match the CPCB IV+ power band

The aftertreatment column is Maxmoc engineering guidance, not part of the notification. The right package depends on engine-out emissions and duty cycle.

Up to 19 kW
NOx + HC 4.7–7.5 g/kWh, PM 0.30 g/kWh: DOC, optional DPF
19 to 56 kW
NOx + HC 4.7 g/kWh, PM 0.03 g/kWh: DOC + DPF, AUS 32-free SCR
56 to 560 kW
NOx 0.40 g/kWh, PM 0.02 g/kWh: DOC + DPF + SCR + ammonia-slip catalyst
560 to 800 kW
NOx 0.67 g/kWh, PM 0.03 g/kWh: DOC + DPF + SCR + ammonia-slip catalyst
Full table and sources
CPCB IV+ emission norms

3. Match the product to the rating

50–150 kW
DOC + DPF System
75–800 kW
Urea SCR System
Installed sets up to 800 kW
Retrofit Emission Control Kit (RECD)

4. Look at how the set runs

Standby sets that run cold or at low load for long periods do not always get hot enough for passive soot burn-off. The Oxidation Booster (15–800 kW) raises the catalyst inlet temperature quickly, and the Active Regeneration Module (up to 1,600 kW) clears the DPF whatever the load.

Every system is sized inside the engine maker’s backpressure limit, so rated output is maintained.

5. Plan for monitoring and service

Online Emission Monitoring gives live status, alerts and regeneration logs for RECD and SCR fleets. Ash cleaning, spares, calibration updates and remote diagnostics through the aftertreatment controller keep the system inside its limits.

Related

Need a system sized for your engine?

Send the engine make, rating and how the set runs. Sizing starts from your engine data and exhaust temperature profile.