Skip to content
NormsGSR 804(E) · genset engines up to 800 kW

CPCB IV+ emission norms for DG sets

The limits every new genset engine up to 800 kW in India must meet, how far they tightened from CPCB II, and what they mean for new and installed DG sets.

CPCB IV+ was notified by the Ministry of Environment, Forest and Climate Change in GSR 804(E) on 3 November 2022 and applies from 1 July 2023 to compression-ignition engines for genset use up to 800 kW. It replaces CPCB II and cuts the allowed NOx and particulate emissions sharply above 56 kW, which in practice means SCR and a diesel particulate filter on most sets.

New engines reach the market through type approval and conformity-of-production testing. DG sets that are already installed follow a different route: a retrofit emission control device where the pollution control board or CAQM asks for one. Our RECD guide covers that route, and the Fitment Studio shows the system fitted to a genset of your size.

▪ The limits

Emission limits for genset CI engines up to 800 kW

Values in g/kWh on the constant-speed or variable-speed test cycle, after deterioration and adjustment factors. Smoke is limited to 0.7 m⁻¹ at every load point. HC is total hydrocarbons for diesel engines.

CPCB IV+ emission limits by engine power
Power, kWNOxHCNOx + HCCOPMTypical aftertreatment
P ≤ 8––7.53.50.30DOC, optional DPF
8 < P ≤ 19––4.73.50.30DOC, EGR or urea-less SCR
19 < P ≤ 56––4.73.50.03DOC + DPF, urea-less SCR
56 < P ≤ 5600.400.19–3.50.02DOC + DPF + Urea SCR + ASC
560 < P ≤ 8000.670.19–3.50.03DOC + DPF + Urea SCR + ASC

Aftertreatment column is Maxmoc engineering guidance, not part of the notification. The right package depends on the engine-out emissions and duty cycle.

▪ How far the limits moved

A 200 kW genset must now emit up to 90 % less

CPCB II limits for 75 to 800 kW engines (GSR 771(E), from 1 July 2014) compared with CPCB IV+ limits for 56 to 560 kW engines (GSR 804(E), from 1 July 2023). Carbon monoxide stays at 3.5 g/kWh in both.

NOx + HC

−0%
CPCB II (2014)0.00 g/kWh
CPCB IV+ (2023)0.00 g/kWh

CPCB IV+ value is 0.40 NOx + 0.19 HC.

Particulate matter

−0%
CPCB II (2014)0.00 g/kWh
CPCB IV+ (2023)0.00 g/kWh

▪ What it means

Above 56 kW, CPCB IV+ means SCR and DPF

Up to 56 kW

A combined NOx + HC limit of 4.7 g/kWh and, from 19 kW, a PM limit of 0.03 g/kWh. A DOC + DPF handles particulates; where NOx margin is tight, our urea-less Urea-Free SCR avoids an AUS 32 tank on small sets.

Learn more →

56 to 560 kW

NOx falls to 0.40 g/kWh and PM to 0.02 g/kWh. In practice that needs urea SCR with an ammonia-slip catalyst plus a wall-flow DPF, as in the Urea SCR platform with closed-loop dosing.

Learn more →

560 to 800 kW

NOx 0.67 g/kWh and PM 0.03 g/kWh. Large SCR volumes, careful mixing and thermal management keep conversion high on low-load standby duty.

Learn more →

▪ Compliance path

New sets, installed sets and local rules

  1. 01

    New gensets: type approval

    Every engine for genset use up to 800 kW made, assembled or imported in India needs type approval and conformity-of-production certification from ARAI, ICAT or IIP before it can be sold or used.

  2. 02

    Conformity of production

    Production units are re-tested every COP year (1 July to 30 June) against the same limits, including deterioration factors, so aftertreatment must hold its performance over time.

  3. 03

    Installed DG sets: retrofit

    Older sets are not covered by CPCB IV+ type approval, but pollution control boards and CAQM require retrofit emission control devices (RECD) with at least 70 % PM capture efficiency on in-use sets in many regions.

  4. 04

    Local tightening