Updated · Maxmoc Motor Works engineering team
What an RECD is
An RECD cleans the exhaust of an in-use DG set without replacing the engine. It combines a diesel oxidation catalyst (DOC), which turns carbon monoxide and unburnt hydrocarbons into CO₂ and water, with a wall-flow diesel particulate filter (DPF), which traps soot and burns it off as CO₂.
Where NOx also has to come down, an SCR stage can be added to the retrofit, with or without an AUS 32 tank.
Who needs an RECD
CPCB IV+ type approval covers new genset engines. Older DG sets are not covered by it, so pollution control boards and the Commission for Air Quality Management (CAQM) require retrofit emission control devices with at least 70 % particulate capture efficiency on in-use sets in many regions.
The requirement is strictest in Delhi NCR and large cities, where several states already restrict DG set operation unless the set is retrofitted or converted to dual fuel. CPCB, CAQM and state boards can also set stricter local norms, so check the current direction for your district.
The Maxmoc RECD at a glance
- Type approval
- ICAT type approval across five filter families, 28.7 kW to 454 kW
- DG set size
- Installed DG sets up to 800 kW
- Particulate reduction
- Up to 99 %
- Backpressure
- Within the engine maker’s limit, so rated output is kept
- NOx option
- SCR add-on, with or without AUS 32
- Fitting
- On site, usually in a single shift
- Product page
- Retrofit Emission Control Kit
How an RECD is fitted
- 01Site survey: a look at the DG set and its exhaust installation.
- 02Sizing and design: the device is sized from your engine data and exhaust temperature profile, inside the engine maker’s backpressure limit.
- 03Installation: the device is usually fitted in a single shift.
- 04Commissioning and emission check: the system is commissioned and checked, and the results go into your compliance file.
Older CPCB I and CPCB II engines
The Maxmoc retrofit system has been tested at ICAT on selected older-generation CPCB I and CPCB II engines, with test reports available for those configurations. Whether a particular set can be brought into compliance depends on the engine model, rating, duty cycle, installation and the approvals that apply, so share your engine data and we will confirm the exact scope against the ICAT reports.
Keeping an RECD working
Nitrogen dioxide from the DOC burns soot continuously at normal exhaust temperatures (passive regeneration). DG sets that run at low load for long periods may need active regeneration, where the Oxidation Booster or the Active Regeneration Module raises the inlet temperature to burn the soot off.
Ash does not burn and is cleaned out at service intervals; DPF Care cleans and reconditions wall-flow filters with a backpressure test before and after. Online Emission Monitoring logs back pressure, temperatures, alerts and regeneration events for pollution control board reports.
Related
Need a system sized for your engine?
Send the engine make, rating and how the set runs. Sizing starts from your engine data and exhaust temperature profile.